Rajeyn launched a new exposed urinal flush valve RJY-21-B102D. It has the same function as RJY-21-B101D and It’s all-in-one type, too which means the sensor, solenoid valve and battery pack are all inside of the flush valve body. But this new type includes a standby manual override. The most important is this manual override is mechanical not electronic, which means the water flush can be activated by the manual knob if the sensor is not working. Below is the general technical parameters.
Product Name | Automatic Urinal Flush 6202D |
Power Supply | DC6V |
Operation Consumption | <60uA |
Dynamic Power Consumption | <180mA |
Sensing Distance | 35-65cm (adjustable) |
Flush Duration | Period 1: about 2 seconds |
Period 2: about 6 seconds | |
Water Pressure | 0.1-0.7 Mpa |
Water Inlet Specification | DN15 (G1/2″) |
Water Flow | 2-5L/flush time (0.3Mpa) |
Similar to regular sensor urinals, the touchfree urinal with manual knob have following features.
#1. Hygiene. Touchless design urinal flush valve provides hands-free and germ-free operation.
#2. Convenience. You just leave the urinal after using, then the urinal flush valve will automatically flush.
#3. Standby manual override. The system will work with the manual knob if the sensor is not working.
#4. Water saving. Water efficient faucet reduces overall water usage without sacrificing water pressure.
#5. Energy saving. Battery shall last approximately 100 times per day for over one year.
This sensor flush conducts twice-flush programming. Pre-flush is 2 seconds and after flush is 6 seconds. The after-flush timing is adjustable by Rajeyn’s remote controller from 3 seconds to 24 seconds based on specific need. The urinal flusher only flushes after-flush if used continuously over 2 times within 1 minute.
Below are trouble shooting during usage.
Problem | Possible Reason | Suggested Solution |
Indicator light doesn’t light up & no flush | Sensing distance is too short | Adjust sensing distance |
No power supply | Please make sure there’s power supply | |
Power adapter broken | Please check power supply and replace power adapter | |
Sensor broken | Replace sensor | |
Indicator light lights up but no flush | Check solenoid connection | Please connect solenoid |
Check water regulating valve or water supply | Please turn on water regulating valve or water supply | |
Filter net block-up | Clean the filter net | |
Solenoid broken | Replace solenoid | |
Sensor broken | Replace sensor | |
Have a continuous water flow problem | Solenoid block-up | Clean the solenoid |
Water pressure is too high or too low | Regulate water pressure to 0.1-0.7 Mpa | |
Low water flow | Check water regulating valve | Regulate water flow |
Filter net block-up | Clean the filter net | |
Water pressure is too low | Regulate water pressure to 0.1-0.7 Mpa |